Old Mutual: Critical Data Centre Infrastructure

Integrated Rack Infrastructure, Power, Cooling, Security & Environmental Monitoring


We were appointed by Old Mutual in Cape Town to deliver a comprehensive data centre infrastructure solution, encompassing rack infrastructure, precision cooling, power distribution, electronic rack access control, environmental monitoring, fire detection and suppression, and complete electrical reticulation.

The objective was to create a secure, resilient and intelligently monitored environment capable of supporting critical IT infrastructure. Our solution integrated Rittal VX IT server racks, metered rack power distribution units (PDUs), precision cooling, hot aisle containment, electronic rack-level access control, AKCP environmental monitoring, VESDA early-warning smoke detection, NOVEC 1230 fire suppression, and dedicated UPS and generator distribution infrastructure.

By bringing these systems together into a coordinated environment, we delivered an integrated infrastructure solution designed to protect critical IT equipment and support operational continuity. Rack-level access control enables controlled access to individual colocation compartments, while environmental monitoring provides visibility of temperature, water ingress, fire system alerts and power failures.

Following installation, system integration, testing and commissioning, we completed the project with comprehensive handover documentation, providing Old Mutual with a professionally engineered infrastructure environment designed to support ongoing operational requirements.

The Challenge


Old Mutual required a robust and secure data centre environment capable of supporting critical IT infrastructure while addressing the risks associated with equipment overheating, unauthorised access, water ingress, fire and power interruptions.

The physical infrastructure needed to accommodate multiple colocation racks, each divided into four compartments, while providing structured equipment accommodation, metered power distribution, effective cable routing and controlled airflow. Dedicated precision cooling was required to manage the thermal loads generated by the IT equipment.

Physical security was another key consideration. Individual colocation compartments required electronic access control to protect critical IT assets and provide a controlled approach to rack-level access management.

The environment also needed continuous monitoring of critical conditions, including temperature fluctuations, water leaks, fire-related alerts and power failures. These capabilities were essential to improving operational visibility and supporting timely responses to potential infrastructure incidents.

In addition, the project required comprehensive electrical reticulation, incorporating UPS and generator distribution, cooling supplies, rack power, lighting, socket outlets, dedicated isolators and equipment earthing.

Our challenge was to bring these interconnected requirements together into one coordinated infrastructure solution, ensuring that the physical, electrical, cooling, security and monitoring systems worked together as a unified environment.

The Solution


We designed and implemented an integrated critical data centre infrastructure solution tailored to Old Mutual’s operational requirements.

The scope included:

  • Rittal VX IT server rack infrastructure: Installation of 13 Rittal VX IT four-compartment colocation racks and two additional Rittal VX IT racks, providing structured accommodation for critical IT equipment.
  • Metered rack power distribution: Deployment of 56 Rittal PDUs, providing monitored 16A single-phase power distribution at compartment rack level.
  • Rack containment and cable management: Rittal containment doors, roof elements, start and end panels, baying connectors, side panels and dedicated cable-routing infrastructure.
  • Hot aisle containment: An airflow management solution designed to support the precision cooling environment and improve the effectiveness of thermal management.
  • Precision cooling: Five Rittal 12kW LCP rack DX precision cooling units, supported by five dedicated remote condensers.
  • Electronic rack access control: Rittal CMC III monitoring and access control, incorporating processing units, CAN-Bus connectivity, 52 electronic access-controlled handles, 52 access control points and seven transponder readers.
  • AKCP environmental monitoring: Monitoring of cold aisle temperatures, flood detection, chilled-water pipe leak detection, fire panel alerts, VESDA alerts and power failure notifications.
  • VESDA aspirating smoke detection: Early-warning smoke detection to identify potential fire conditions within the critical environment.
  • NOVEC 1230 fire suppression: Dedicated fire suppression infrastructure providing an additional layer of protection for the critical data centre environment.
  • Custom UPS Distribution Boards A and B: Dedicated electrical distribution infrastructure supporting critical equipment power requirements.
  • Generator Distribution Board: Dedicated generator-backed electrical distribution.
  • General Distribution Board: Electrical distribution supporting the facility’s general power requirements.
  • Complete electrical reticulation: Power feeds for cooling condensers, UPS and generator distribution, rack power, lighting, socket outlets and dedicated equipment isolators.
  • Equipment earthing and bonding: Dedicated earthing infrastructure supporting the electrical installation.
  • Secure cage partition: Installation of a secure cage partition with a single gate, providing an additional layer of physical security.
  • System integration and handover: Integration and testing of the installed infrastructure, supported by comprehensive project documentation for ongoing operation and maintenance.

      By integrating rack infrastructure, power distribution, precision cooling, physical access control, fire protection and environmental monitoring, we delivered a coordinated critical environment designed around Old Mutual’s infrastructure requirements.

        IMplementation


        We managed the project through the complete delivery lifecycle, from system design and equipment supply through to installation, integration, commissioning, testing and final handover.

        The Rittal VX IT rack infrastructure established the physical foundation of the environment. The racks were configured with the required containment, side panels, cable routing and metered PDUs to provide an organised and maintainable equipment installation.

        Five Rittal 12kW precision cooling units and their associated remote condensers were installed to provide dedicated cooling capacity. The cooling infrastructure was coordinated with the hot aisle containment arrangement to support controlled airflow and stable operating conditions.

        We implemented rack-level electronic access control using the Rittal CMC III platform, integrating the access-controlled handles, processing units and transponder readers to provide controlled access to individual cabinet compartments.

        The AKCP environmental monitoring system was configured to monitor critical environmental and infrastructure conditions. Flood sensors were positioned within the room and above equipment, while flood-strip detection was installed in the drip-tray area associated with existing piping. The monitoring environment also received alerts from the fire panel and VESDA system, as well as power failure notifications.

        Our electrical scope included custom UPS, generator and general distribution boards, complete electrical reticulation, condenser supplies, equipment earthing, lighting, socket outlets and dedicated isolators for the fire detection and monitoring systems.

        Following installation, comprehensive testing and commissioning were undertaken to verify the operation of individual systems and their integration with the wider infrastructure environment. The project concluded with the compilation and submission of a complete handover file to Old Mutual.

        Results & Impact


        • Structured critical IT infrastructure: A professionally engineered Rittal VX IT rack environment comprising 13 four-compartment colocation racks and two additional IT racks.
        • Metered rack-level power distribution: 56 Rittal PDUs providing monitored power distribution across the rack environment.
        • Dedicated precision cooling: Five 12kW Rittal LCP rack DX cooling units supporting the thermal requirements of critical IT equipment.
        • Controlled physical access: Electronic access control across 52 access points, supporting the protection of individual colocation compartments.
        • Enhanced environmental visibility: Integrated monitoring of temperature, water-related conditions, fire system alerts and power failures.
        • Early-warning fire detection and suppression: VESDA aspirating smoke detection and NOVEC 1230 fire suppression within the critical environment.
        • Coordinated electrical infrastructure: Dedicated UPS and generator distribution, general electrical distribution, equipment earthing and complete reticulation.
        • Airflow management: Hot aisle containment supporting the precision cooling environment.
        • Integrated infrastructure systems: Coordinated rack, power, cooling, security and monitoring technologies within one critical environment.
        • Maintainable infrastructure: Organised equipment and cable routing, comprehensive testing and commissioning, and complete handover documentation.

        The result is a secure, integrated and scalable infrastructure environment designed to support the protection, monitoring and ongoing operation of Old Mutual’s critical IT systems.

          Conclusion


          This project demonstrates our ability to design and deliver integrated critical infrastructure solutions for environments where equipment protection, physical security, environmental control and electrical resilience are essential.

          By bringing together Rittal rack infrastructure, metered power distribution, precision cooling, electronic access control, AKCP environmental monitoring, VESDA early-warning smoke detection, NOVEC 1230 fire suppression and comprehensive electrical distribution, we delivered a coordinated infrastructure solution rather than a collection of standalone systems.

          This integrated approach provides Old Mutual with greater visibility of critical environmental conditions, controlled access to IT equipment, dedicated cooling and power infrastructure, and additional protection against potential environmental and fire-related incidents.

          Through specialist technology, integrated engineering and disciplined project execution, we brought multiple infrastructure disciplines together into one professionally engineered environment, aligned with the operational requirements of a leading financial services organisation.

          Multi-system Infrastructure Specialist. Orchestrating Complex Infrastructure.